Convenient Control
Regardless of whether you need to control hoists from ground level or want to control machinery, wire-connected DSK control pendants are the ideal solution.
- High level of safety
- For direct or contactor control
- Ergonomic design and operation
High safety and reliability
- Mechanical interlocking of the switching elements
- Movements in opposite directions cannot be simultaneously actuated
Performance to meet application requirements
- Direct control of drives with motor outputs up to 5.5 kW by using various switching elements
- Indirect control using contactors in the auxiliary circuit for higher outputs
Convenient operation
- Fatigue-free operation thanks to the ergonomical housing design
- Sloping control pendant design permits operators to work in a natural, comfortable posture
Customisable
- Can be configured to customer specifications (e.g. cable length)
Technical Data
DSK series control pendants offer the following outstanding technical details:
- Permissible ambient temperatures from -25 °C to 70 °C
Control
- CBDN switching element (emergency stop) with positive opening of the NC contacts
- Direct control of drives up to 5.5 kW
- Simultaneous 2-pole switching for direct control
- Switching elements for direct or contactor control
Housing
- High-quality thermoplastic housing that is highly resistant to impacts
- Non-flammable, climate and corrosion-proof
- Highly resistant to fuels, salt water, grease, oils and alkaline solutions
Safety
- Strain relief by means of special hose with additional protective sleeve, as standard
- Protective insulation to DIN VDE 0100 Part 410
- Switching distances and forces to DIN 33401, holding force < 8 N
- IP 55 enclosure to DIN VDE 0470 as standard in "suspended" operating position
- IP65 on request
Main current switching elements |
Type |
CBD 1 |
CBD 2 |
CBDN |
Design |
Single-stage switching element 2 NO |
Double-stage switching element 2 NO in the 1st stage 2 changeover contacts in the 2nd stage |
Single-stage crane switch (emergency stop), 3 NC |
Rated operating voltage [V] |
230 |
400 |
500 |
230 |
400 |
500 |
Rated operating current [A] |
20 |
12 |
9 |
Ith 2 |
25 |
|
Utilisation category to DIN VDE 0660 / EN 60947 Main current |
AC 3, AC 4 |
AC 3, AC 4 |
for breaking capacity up to 5.5 kW |
Nominal insulation voltage |
Ui 500 V~ to DIN VDE 0110, CSA 300 VAC |